4300 Results for: "Ace+Method+Development+Kits"
Avantor® ACE® ChromSword, HPLC/UHPLC Columns, Method Development Kits
Supplier: Avantor
Solve U/HPLC method development challenges systematically and efficiently using Avantor® ACE® columns and ChromSword 5.1 Lite method development software. The Avantor® ACE® ChromSword Method Development Kit includes six alternative selectivity Avantor® ACE® phases, a copy of ChromSword 5.1 Lite offline with a six month activation licence and a lot of technical information and support.
Expand 35 Items
Avantor® ACE®, HPLC/UHPLC Columns, HILIC Method Development Kits, Analytical
Supplier: Avantor
Avantor® ACE® HILIC method development kits offer all three Avantor® ACE® proprietary HILIC phases (HILIC-A, HILIC-B and HILIC-N) in one kit. These phases offer alternative HILIC selectivity to each other, and have been developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 28 Items
Avantor® ACE®, HPLC Columns, Bioanalytical 300 Å Method Development Kits, 3 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 9 Items
Avantor® ACE®, HPLC/UHPLC Columns, Advanced Method Development Kits, 5 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 12 Items
Avantor® ACE®, HPLC/UHPLC Columns, Extended Method Development Kits, 5 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 12 Items
Avantor® ACE®, HPLC/UHPLC Columns, Advanced Method Development Kits, 1,7 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 5 Items
Avantor® ACE®, HPLC/UHPLC Columns, Extended Method Development Kits, 1,7 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 5 Items
Avantor® ACE®, HPLC/UHPLC Columns, Extended Method Development Kits, 2 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 9 Items
Avantor® ACE® UltraCore, HPLC/UHPLC Columns, Method Development Kits, 2,5 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximize selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness. A complete range of kits for all requirements is available, including porous, solid core, HILIC and bioanalytical 300 Å column kits. These kits group together the essential column chemistries for method development and are available in a wide range of column formats.
Expand 9 Items
Avantor® ACE® UltraCore, HPLC/UHPLC Columns, Method Development Kits, 5 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximize selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness. A complete range of kits for all requirements is available, including porous, solid core, HILIC and bioanalytical 300 Å column kits. These kits group together the essential column chemistries for method development and are available in a wide range of column formats.
Expand 12 Items
Avantor® ACE®, HPLC/UHPLC Columns, Advanced Method Development Kits, 3 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 12 Items
Avantor® ACE®, HPLC/UHPLC Columns, Advanced Method Development Kits, 2 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 9 Items
Avantor® ACE®, HPLC Columns, Bioanalytical 300 Å Method Development Kits, 5 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 12 Items
Avantor® ACE®, HPLC/UHPLC Columns, Extended Method Development Kits, 3 µm
Supplier: Avantor
Avantor® ACE® Method Development Kits (MDK) are designed to maximise selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness.
Expand 12 Items
Avantor® ACE® HILIC-N, HPLC/UHPLC Columns, Analytical
Supplier: Avantor
Avantor® ACE® HILIC-N columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 50 Items
Avantor® ACE® HILIC-A, HPLC/UHPLC Columns, Analytical
Supplier: Avantor
Avantor® ACE® HILIC-A columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 53 Items
Avantor® ACE® HILIC-B, HPLC/UHPLC Columns, Analytical
Supplier: Avantor
Avantor® ACE® HILIC-B columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 37 Items
Avantor® ACE® HILIC-B, HPLC Columns, 5 µm
Supplier: Avantor
Avantor® ACE® HILIC-B columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 16 Items
Suite of columns, Cogent TYPE-C™, method development kits
Supplier: MICROSOLV
The Cogent suite of columns is set of 5 columns of the same configuration consisting of one each of the Bidentate C18™, UDC-Cholesterol™, Bidentate C8™, Diamond Hydride™ and Silica C™.
Expand 1 Items
J.T.Baker® BAKERBOND®, SPE 96-Well Plates
Supplier: Avantor
Solid Phase Extraction (SPE) is commonly used as a highly selective sample clean-up or sample enrichment method prior to subsequent analyses. J.T.Baker® BAKERBOND® SPE 96 well plates are well suited for high throughput and automated SPE methods. With complementary high capacity sorbents to existing spe extraction columns in the J.T.Baker® BAKERBOND® range, higher throughput methodologies can now be simply developed and automated.
Expand 27 Items
Methanol ≥99.8% (by GC, corrected for water content), ULTRA RESI-ANALYZED® for organic residue analysis, J.T.Baker®
Supplier: Avantor
BAKER ULTRA RESI-ANALYZED® Reagent—ultra high-purity solvents and salts developed for organic residue extraction/concentration procedures. These solvents are fully characterized and lot controlled by ECD, FID, or other method-specific detectors. Advanced stabilizer systems are incorporated to ensure solvent stability and superior performance Solvents are suitable for exacting EPA sample cleanup protocols.
Expand 3 Items
J.T.Baker® BAKERBOND® Q2100, New Generation UHPLC and HPLC Columns
Supplier: Avantor
BAKERBOND® Q2100 LC phases have been specially designed to solve the challenges of most routine samples. They can also be a good starting point for new method development projects. With options of four widely used chemistries and three particle sizes BAKERBOND® Q2100 can be a useful addition to your analytical toolkit.
Expand 72 Items
Sodium sulphate, anhydrous ≥99.0%, granular, ULTRA RESI-ANALYZED® ACS 12-60 Mesh for pesticide residue analysis, J.T.Baker®
Supplier: Avantor
BAKER ULTRA RESI-ANALYZED® Reagent ultra high purity solvents and salts developed for organic residue extraction/concentration procedures.
Expand 4 Items
Sodium hydroxide 5 N in aqueous solution, BAKER ANALYZED® volumetric solution, J.T.Baker®
Supplier: Avantor
J.T.Baker® volumetric and analytical solutions. These solutions are suitable for use in ACS, USP and NF compendial methods and general laboratory applications.
Expand 4 Items
Ammonia solution 28.0 - 30.0% (NH₃ basis), AR Select® ACS for trace metal analysis, Macron Fine Chemicals™
Supplier: MACRON AVANTOR BRAND
AR Select® - A line of acids specifically developed for trace metal analysis; analysed for up to 32 metals in the low ppb range.
Expand 2 Items
Avantor® ACE® Excel® C18-PFP, HPLC/UHPLC Columns, Analytical, 2 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
Expand 17 Items
Avantor® ACE® Excel® C18-PFP, HPLC/UHPLC Columns, Analytical, 1,7 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
Expand 10 Items
Avantor® ACE® Excel® C18-PFP, HPLC/UHPLC Columns, Analytical, 3 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
Expand 19 Items
Avantor® ACE® Excel® C18-AR, HPLC/UHPLC Columns, Analytical, 1,7 µm
Supplier: Avantor
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
Expand 10 Items
Avantor® ACE® C18-PFP, HPLC Columns, 5 µm
Supplier: Avantor
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.